+86 18819144521 [email protected] +86 18819144521
,

UMY-MRI035 0.35T Open Permanent Magnet MRI System

The 0.35T open permanent magnet MRI system combines a C-shaped Nd-Fe-B magnet, 4-channel digital RF acquisition, configurable receiving coils, a 200 kg manual patient table and a Windows-based MRI workstation. The open low-field configuration is designed for routine MRI imaging workflows with flexible coil selection and lower infrastructure requirements compared with superconducting MRI systems.

0.35T Open Permanent Magnet MRI System

This 0.35T MRI system uses an open C-shaped permanent magnet architecture for routine magnetic resonance imaging. The system combines an Nd-Fe-B permanent magnet, 4-channel digital RF acquisition, configurable receiving coils, a manual patient table and a Windows-based MRI workstation.

The low-field permanent magnet design is intended for medical facilities requiring an open MRI configuration with straightforward daily operation, flexible anatomical coil selection and no superconducting magnet helium system.

System Highlights

0.35T Permanent Magnet

The system uses a 0.35 Tesla permanent magnet constructed with Nd-Fe-B magnetic material and an automatic constant-temperature magnet control system.

Open C-Shaped Design

The C-shaped magnet provides open lateral access around the patient and supports positioning for routine low-field MRI examinations.

4-Channel Digital RF System

An all-digital 4-channel spectrometer supports MR signal acquisition and works with dedicated receiving coils for different anatomical regions.

Configurable Receiving Coils

The receiving coil package can be configured according to the examination requirements of the hospital or imaging center.

200 kg Patient Table

A manually operated patient table supports up to 200 kg and is designed for straightforward positioning in the low-field permanent magnet system.

Windows-Based MRI Workstation

The operator workstation uses a Windows platform with a 24-inch display and supports integration with DICOM printing and RIS workflows according to the installed configuration.

0.35T Open Permanent Magnet

The magnet system uses a C-shaped open architecture with a magnetic field strength of 0.35 Tesla. High-grade Nd-Fe-B magnetic material is used in the permanent magnet assembly.

An automatic constant-temperature control system is incorporated to help maintain magnet operating conditions during routine system use.

Digital RF Acquisition

The MRI platform uses an all-digital 4-channel spectrometer for RF signal acquisition. The supplied product information specifies approximately four minutes for selected routine imaging sequences, depending on protocol and examination settings.

RF Architecture All-Digital
RF Channels 4 Channels
Routine Sequence Time Approx. 4 minutes for selected sequences

Receiving Coil Options

The system supports multiple dedicated receiving coils for different anatomical regions. Five coils can be configured as a standard package according to the project, while additional coil options can be selected based on clinical requirements.

Head Coil Available
Neck Coil Available
Large Body Coil Available
Small Body Coil Available
Knee Coil Available
Shoulder Coil Available
Ankle Coil Available
Wrist Coil Available
Standard Configuration 5 coils, final selection subject to project configuration

Manual Patient Table

The 0.35T permanent magnet MRI system uses a manually operated patient table with horizontal positioning. The manual mechanism provides a simple positioning structure without requiring an electric table drive system.

Patient Table Type Manual
Positioning Manual horizontal movement
Maximum Patient Load 200 kg

MRI Workstation

The MRI workstation provides the operator interface for examination setup, scanning and routine image management. The supplied configuration uses a Windows operating platform and a 24-inch display.

Operating Platform Windows
Display 24-inch monitor
DICOM Printing Supported according to installed configuration
RIS Integration Supported according to installed configuration
MRI Operation Software Included

Typical Imaging Applications

With the appropriate receiving coils and installed software package, the 0.35T open MRI platform can be configured for routine examinations across multiple anatomical regions.

  • Brain and head MRI.
  • Neck and cervical imaging.
  • Spine examinations.
  • Knee and other joint imaging.
  • Shoulder imaging.
  • Wrist and ankle imaging.
  • Selected body MRI examinations with the appropriate body coil.

Available pulse sequences and advanced imaging applications should be confirmed according to the final software and coil configuration before ordering.

Technical Specifications

System Type Open Permanent Magnet MRI System
Magnetic Field Strength 0.35T
Magnet Shape Open C-Shaped
Magnet Material Nd-Fe-B Permanent Magnet
Magnet Temperature Control Automatic Constant-Temperature Control
RF Acquisition All-Digital
RF Channels 4 Channels
Coil Configuration 5 coils standard configuration; additional options available
Patient Table Manual
Maximum Patient Load 200 kg
Workstation Platform Windows
Workstation Display 24-inch Monitor
DICOM / RIS Supported according to system configuration

Before Ordering

The final MRI configuration depends on the intended examinations, coil package, installed software and site conditions. Please provide the following information when requesting a quotation.

  • Required quantity and destination country.
  • Expected MRI examination types.
  • Required receiving coil configuration.
  • Expected daily patient volume.
  • Required MRI software and imaging applications.
  • Available MRI room dimensions and site layout.
  • Local power supply conditions.
  • RF shielding and room preparation status.
  • DICOM, PACS or RIS integration requirements.
  • Required installation, training and technical support.
  • Local registration, tender or documentation requirements.

Frequently Asked Questions

What type of magnet does this MRI system use?

The system uses a 0.35T permanent magnet with an open C-shaped architecture and Nd-Fe-B magnetic material.

How many RF channels does the system provide?

The supplied configuration uses an all-digital 4-channel RF acquisition system.

Which receiving coils are available?

Available coil options include head, neck, large body, small body, knee, shoulder, ankle and wrist coils. The standard five-coil package should be confirmed according to the final project configuration.

What is the maximum patient table load?

The manual patient table is specified for a maximum patient weight of 200 kg.

Does the workstation support hospital information systems?

The supplied information specifies compatibility with DICOM printing and RIS systems. The required interfaces should be confirmed for each project before ordering.

Which MRI examinations can be performed?

The available examination range depends on the receiving coils and installed software package. Please provide the intended applications so the appropriate system configuration can be confirmed.

Reviews

There are no reviews yet.

Be the first to review “UMY-MRI035 0.35T Open Permanent Magnet MRI System”

Your email address will not be published. Required fields are marked *

Scroll to Top