Vitagas Blood Gas Analyzer
The Vitagas series is a blood gas analyzer designed for rapid blood gas, electrolyte and related parameter testing in clinical laboratories, intensive care, emergency medicine, anesthesiology and other critical-care environments.
Depending on the selected model, the system supports pH, pO₂, pCO₂, Hct, K+, Na+, Cl-, Ca²+, glucose and lactate measurement. Sample analysis is completed in approximately 60 seconds for standard parameters, while Lac/Glu analysis is specified at less than 90 seconds.
The analyzer combines automatic sample aspiration, integrated quality-control functions, a 12.1-inch color touchscreen, bi-directional LIS connectivity, WiFi, 4G, barcode scanning and thermal printing in a laboratory-oriented platform.
Key Features
Rapid Blood Gas Analysis
Standard sample analysis is completed in approximately 60 seconds, while configurations including lactate or glucose are specified at less than 90 seconds.
Low Sample Volume
The specified blood volume for full-parameter testing is less than 170 μL, supporting routine blood gas testing workflows with limited sample volume.
Multiple Parameter Configurations
Vitagas 5, 5A, 5B and 5E configurations cover different combinations of blood gas, electrolyte, hematocrit, glucose and lactate parameters.
Automatic Sample Handling
Automatic sample aspiration and sample-needle cleaning support capillary samples, arterial blood syringes and test tubes.
Integrated Quality Control
Built-in multi-level quality-control rules, QC charts and QC data management support routine laboratory quality-management workflows.
LIS and Wireless Connectivity
Supports bi-directional LIS communication together with built-in WiFi, 4G and remote maintenance functions.
Applications
The Vitagas blood gas analyzer is intended for blood gas, acid-base, oxygenation, ventilation and related parameter assessment across clinical and critical-care environments.
- Clinical laboratory blood gas testing.
- Intensive care and critical-patient monitoring.
- Emergency and respiratory care workflows.
- Ventilator and oxygen-therapy monitoring.
- Perioperative and anesthesia monitoring.
- Neonatal and pediatric blood gas analysis.
- Cardiology and cardiac surgery applications.
- Renal and hemodialysis-related monitoring workflows.
Sample Types
The analyzer supports multiple clinical sample types according to the selected testing workflow.
- Whole blood.
- Arterial blood.
- Venous blood.
- Serum.
- Plasma.
- Cerebrospinal fluid (CSF).
Model and Test Parameter Options
| Vitagas 5 | pH, pO₂, pCO₂, Hct, K+, Na+, Cl-, Ca²+ |
|---|---|
| Vitagas 5A | pH, pO₂, pCO₂, Hct |
| Vitagas 5B | pH, pO₂, pCO₂, Hct, Glu, Lac |
| Vitagas 5E | pH, pO₂, pCO₂, Hct, K+, Na+, Cl-, Ca²+, Glu, Lac |
Calculated Parameters
The system provides more than 32 calculated parameters depending on the selected testing configuration.
| Blood Gas and Acid-Base | pH(TC), pCO₂(TC), pO₂(TC), TCO₂, HCO₃, BE, BEecf, SBC, SO₂% |
|---|---|
| Electrolyte and Metabolic | nCa²+(7.4), TCa²+, AG, AG(K+), mOsm |
| Oxygenation | RI, pO₂(A-a), P50, pO₂/FiO₂, pO₂(TC)/FiO₂, pO₂(a/A) |
| Blood Content Calculations | THb, ctO₂, ctCO₂(p), ctCO₂(B) |
| Arteriovenous Calculations | ScvO₂, pCO₂ gap, CaO₂, CvO₂, CaCO₂, CvCO₂, SaO₂, SvO₂, VO₂, VCO₂ |
Technical Specifications
| Product Type | Blood Gas Analyzer |
|---|---|
| Models | Vitagas 5 / Vitagas 5A / Vitagas 5B / Vitagas 5E |
| Analysis Time | Approximately 60 seconds; Lac / Glu less than 90 seconds |
| Sample Volume | <170 μL for full-parameter testing |
| Display | 12.1-inch color LCD touchscreen |
| Sample Aspiration | Automatic |
| Sample Needle Cleaning | Automatic |
| Quality Control | Multi-level QC rules, QC charts and QC data management |
| Data Communication | Bi-directional LIS |
| Wireless Connectivity | Built-in WiFi and 4G |
| Barcode Scanner | Built-in 2D barcode scanner |
| Printer | Built-in thermal printer; external USB printer supported |
| Power Backup | Built-in UPS |
| Optional Accessories | Trolley and external large-capacity UPS |
| Data Storage | Large-capacity data storage |
| Remote Support | Remote maintenance system |
Reagent Pack Configuration
Multi-specification reagent packs are available for different laboratory testing volumes. The catalogue specifies reagent-pack capacities from 50 tests per pack up to 1200 tests per pack.
The reagent packs can be stored at room temperature for up to 9 months and are specified for up to 45 days of on-board use.
An integrated flush-solution pack is provided as part of the fluid-management configuration. Final reagent-pack size and test volume should be confirmed according to laboratory workload and quotation requirements.
Glucose and Lactate Testing
Vitagas configurations supporting glucose and lactate use a disposable dry lactate-glucose electrode. The catalogue specifies an in-use period of up to 30 days for this electrode.
Glucose and lactate availability depends on the selected analyzer model and should be confirmed when selecting Vitagas 5B or Vitagas 5E.
Laboratory Connectivity and Data Management
The analyzer supports bi-directional LIS communication for laboratory information exchange. Built-in WiFi and 4G connectivity are provided together with remote maintenance support.
A built-in 2D barcode scanner supports sample and workflow identification, while test results and quality-control data can be stored, printed and exported according to laboratory requirements.
Before Ordering
Please provide the following information so the appropriate blood gas analyzer model, reagent configuration and laboratory interface requirements can be confirmed before quotation.
- Required analyzer quantity.
- Destination country.
- Required test parameters.
- Whether electrolyte testing is required.
- Whether glucose and lactate testing are required.
- Expected daily or monthly test volume.
- Required reagent-pack capacity.
- Required LIS connectivity.
- Whether a trolley or external UPS is required.
- Any tender, installation or documentation requirements.
Frequently Asked Questions
What parameters can the Vitagas blood gas analyzer measure?
Depending on the selected model, the analyzer can measure pH, pO₂, pCO₂, Hct, K+, Na+, Cl-, Ca²+, glucose and lactate.
How fast is the blood gas analysis?
Standard sample analysis is specified at approximately 60 seconds. Testing configurations including lactate or glucose are specified at less than 90 seconds.
How much sample is required?
The specified blood volume for full-parameter testing is less than 170 μL.
Does the analyzer support LIS connectivity?
Yes. The system supports bi-directional LIS communication together with WiFi, 4G and remote maintenance functions.
What reagent-pack sizes are available?
The catalogue specifies multiple reagent-pack configurations ranging from 50 to 1200 tests per pack. Final selection should be based on laboratory workload.
Which model supports glucose and lactate testing?
Vitagas 5B and Vitagas 5E include glucose and lactate in their listed parameter configurations.