UMVXRAY025 500W Handheld X-Ray Machine is a portable, battery-powered radiographic unit with dedicated human and veterinary imaging modes. It combines selectable tube voltage and current, adjustable square collimation, touchscreen controls and remote exposure operation. The unit can be configured with a compatible wired or wireless flat-panel detector and image acquisition workstation for human or veterinary radiography, subject to the applicable clinical-use authorization.
500W Handheld X-Ray Performance and Adjustable Exposure Control
The UMVXRAY025 is positioned as a 500W-class handheld X-ray machine. Its highest available 70 kV operating point is 7 mA, equivalent to 490 W of calculated instantaneous electrical X-ray tube input. The 500W designation is a nominal product class rather than a separate measured output specification. It offers three tube-voltage selections (50, 60 and 70 kV) and six tube-current selections (2, 3.5, 5, 6, 7 and 8 mA). At 70 kV, the highest available tube current is 7 mA. Exposure duration can be adjusted from 0.01 to 2.00 seconds to suit the selected examination and digital detector workflow.
- High-frequency X-ray generation: DC high-voltage output supports radiographic exposures.
- Adjustable collimation: Square X-ray field with an adjustable collimator for controlling the area irradiated.
- Touchscreen control: Set tube voltage, tube current, exposure time and anatomical selections through the device interface.
- Remote exposure: Wireless remote control allows qualified personnel to initiate exposure from a suitable protected position.
- Handheld or mounted positioning: Can be used by hand or secured on a suitable tripod or fixing device.
Dual Human and Veterinary Radiography Modes
UMVXRAY025 includes two dedicated operating modes for human and veterinary examination workflows. The human interface offers body-size and region selections for head, chest, hand and foot examinations. The veterinary interface provides large, medium and small animal selections with head, thorax/abdomen, spine and limb regions.
Both interfaces provide access to exposure settings and status information. Use of the equipment in any clinical setting is subject to its approved intended use, operator qualifications and applicable local registration and radiation-protection requirements.
Adjustable Collimator and Practical Alignment
The integrated square collimator helps the operator adjust the exposed field for the selected examination. A built-in collimator LED supports positioning and alignment. The gyroscope angle display can be switched on or off to help review device orientation while preparing the exposure.
A nominal source-to-skin distance of 200 mm and total filtration of greater than 2.0 mm Al are specified for the unit. Appropriate exposure technique and beam limitation must be determined by qualified radiographic personnel.
Digital Imaging with Wired or Wireless Flat Panel Detectors
The UMVXRAY025 is an X-ray source, not a standalone image-capturing detector. Diagnostic image acquisition requires a compatible digital X-ray sensor or flat-panel detector, image acquisition software and, where applicable, a workstation.
Depending on the examination workflow, a wired or wireless flat panel detector can be considered. For wired installations, data transfer can be organized around a cable-connected imaging station. Wireless detectors may provide more positioning flexibility. Detector trigger mode, exposure synchronization, physical field coverage, imaging software and network interface must be reviewed as part of system integration.
| Detector configuration | UMY Medical product options |
|---|---|
| Wired digital detector | 17 × 17-Inch Wired Flat Panel Detector — for suitability and synchronization review. |
| Wireless digital detector | Wireless Veterinary Flat Panel Detector — for wireless system configuration review. |
| Additional options | Explore UMY Medical X-Ray Flat Panel Detectors. |
The detector and acquisition workstation are separate configuration items unless expressly included in the quotation. The linked models are options for compatibility review rather than confirmed plug-and-play matches.
Technical Specifications
| Specification | UMVXRAY025 |
|---|---|
| Product type | 500W-class handheld collimated X-ray machine for human and veterinary imaging workflows |
| Power designation | 500W class (nominal product positioning); calculated 70 kV × 7 mA operating point: 490 W |
| Operating modes | Human and Veterinary touchscreen modes |
| Model | UMVXRAY025 |
| Tube voltage | 50 / 60 / 70 kV |
| Tube current selections | 2 / 3.5 / 5 / 6 / 7 / 8 mA; at 70 kV, up to 7 mA |
| Exposure time | 0.01–2.00 seconds |
| Collimator | Adjustable square X-ray field |
| Nominal source-to-skin distance | 200 mm |
| Total filtration | >2.0 mm Al |
| X-ray tube model | D-045 |
| X-ray tube nominal voltage | 70 kV |
| X-ray tube nominal anode input power | 0.585 kW (tube rating; not the device’s selectable operating output) |
| Focal spot size | 0.4 |
| Target material / angle | Tungsten / 12.5° |
| Anode heat capacity | 4.3 kJ |
| Maximum continuous cooling power | 100 W |
| Battery | Rechargeable lithium-ion polymer, 22.2 V DC, 2,100 mAh |
| Power adapter input | 100–240 VAC, 50/60 Hz |
| Power adapter output | 25.2 V DC, 1.0 A |
| Electrical protection | Internally powered unit; Class II charging adapter |
| Ingress protection | IPX0 |
| Orientation indication | Gyroscope angle display, –90° to +90° |
| Operating temperature / humidity | 0–40°C / 30–70% RH |
| Device dimensions (from dimensional drawing) | 185.9 × 126 × 135.1 mm overall; housing depth indication 82.4 mm |
| Nominal service life | 5 years or 10,000 exposures |
Touchscreen Workflow and Remote Exposure
- Direct controls: Quickly adjust exposure duration using the on-screen + and – controls and save selected exposure parameters.
- Preset examination selection: Choose the applicable operating interface, patient or animal size and region before an examination.
- Exposure status: On-screen STANDBY/LOCKED status helps operators distinguish readiness from the required post-exposure cooling interval.
- Remote operation: The wireless remote control supports exposure initiation while the operator follows the required shielding, positioning and radiation-safety procedures.
- Battery monitoring: The display indicates remaining power and prompts recharging when the battery becomes low.
System Components and Configuration
| Component | Details |
|---|---|
| Handheld X-ray unit | UMVXRAY025 (unit identified as RV-350RH in the accessories list) |
| Power adapter | PSY2521000 |
| Remote control | DSC-TC341465 |
| Digital detector and imaging software | Select according to requested imaging configuration; separate quotation item |
| Tripod / fixing solution | Confirm suitable mounting requirements when ordering |
Radiation Safety and Installation
UMVXRAY025 generates ionizing radiation and may only be operated by appropriately trained and authorized personnel. Imaging must take place in a controlled examination environment with suitable shielding and radiation-protection procedures. The installation documentation calls for a lead-shielded room; applicable local requirements and an appropriate radiation-protection assessment must be satisfied before clinical use.
Use an appropriate protected operating position, avoid exposure to personnel in the primary beam and follow applicable protective-equipment requirements. The unit is not designed to produce exposures while connected to its charger.
Frequently Asked Questions
What are the advantages of the UMVXRAY025 500W handheld X-ray machine?
UMVXRAY025 combines human/veterinary operating modes, adjustable collimation, six selectable tube-current levels and three tube-voltage settings, allowing flexible exposure-parameter selection. The 70 kV setting supports a maximum current of 7 mA.
What exposure time can be selected?
Exposure time is adjustable from 0.01 to 2.00 seconds. These values describe the X-ray emission duration, not the time required for detector readout or image display.
Can the unit be used with a wired or wireless flat panel detector?
Wired and wireless digital detector configurations can be assessed. A compatible detector, acquisition software and suitable exposure triggering or synchronization are required for image capture. UMY Medical can review your intended detector and workstation arrangement before quotation.
Can UMVXRAY025 support both human and veterinary examinations?
Yes. UMVXRAY025 features separate human and veterinary interface modes with dedicated body-size and anatomical-region selections. Confirm the applicable clinical-use approvals for the destination country before deployment.
Is the X-ray detector included?
The X-ray unit and related accessories can be specified separately from a detector and workstation. Please confirm the exact package when requesting a quotation.
Can the unit be used while charging?
No. X-ray exposure is disabled while the charger is connected and the battery is charging.
What should I send to request a quotation?
Please specify the destination country, quantity, intended examinations, local regulatory requirements, desired wired or wireless detector, required acquisition workstation and mounting arrangement.
Request a UMVXRAY025 Quotation
Contact UMY Medical for a configuration review covering the X-ray unit, matching detector, acquisition software, workstation and any mounting or documentation requirements.
Related equipment: Explore digital X-ray flat panel detectors and veterinary radiology equipment from UMY Medical.









Reviews
There are no reviews yet.