This semi-automatic urine analyzer supports 8-, 10- and 11-parameter urinalysis with testing speeds up to 120 tests/hour. It features cold-light reflection photometry, automatic excess urine absorption, storage for up to 1,000 results, a built-in thermal printer and RS232 connectivity for laboratory data management.

Semi-Automatic Urine Analyzer

This semi-automatic urine analyzer is designed for routine urinalysis in hospitals, clinics and diagnostic laboratories. The system supports 8-, 10- and 11-parameter urine test strip configurations and provides testing speeds of up to 120 tests per hour in continuous test mode.

Cold-light reflection photometry is used for strip measurement, while an automatic excess urine absorption function helps remove residual liquid from the test strip and reduce carryover during routine testing. Built-in result storage, thermal printing and RS232 communication support day-to-day laboratory workflow and data management.

Key Features

Up to 120 Tests per Hour

Continuous test mode supports throughput of up to 120 urine strip tests per hour for routine clinical laboratory workflows.

Cold-Light Reflection Photometry

The analyzer uses a high-luminosity cold-light reflection photometry system for quantitative interpretation of urine reagent strips.

8, 10 and 11-Parameter Testing

Multiple urine test strip configurations are supported for routine screening requirements. Final strip compatibility should be confirmed according to the selected reagent strip.

Automatic Excess Urine Absorption

The automatic liquid-absorption mechanism removes excess urine from the test strip to help reduce residual liquid and sample carryover during testing.

1,000-Result Storage

Up to 1,000 test results can be stored for routine result review and laboratory record management.

Built-In Thermal Printer

An integrated thermal printer provides immediate printing of urine test results without requiring a separate printer for routine operation.

Applications

The analyzer is intended for routine urine chemistry screening in clinical and diagnostic laboratory environments.

  • Hospital clinical laboratories.
  • Outpatient and community clinics.
  • Diagnostic laboratories.
  • Routine urinalysis screening.
  • Urinary tract infection screening workflows.
  • Renal and metabolic screening support.
  • Health examination and routine check-up laboratories.

Urine Test Parameters

The 11-parameter configuration supports the following urine chemistry test items.

VC Ascorbic Acid
LEU Leukocytes
NIT Nitrite
URO Urobilinogen
PRO Protein
pH Urine pH
BLD Blood
SG Specific Gravity
KET Ketones
BIL Bilirubin
GLU Glucose

Testing and Measurement

Product Type Semi-Automatic Urine Analyzer
Measurement Principle Cold-light reflection photometry
Testing Speed Up to 120 tests/hour
Testing Mode Continuous test mode
Strip Configurations 8, 10 and 11 parameters
Maximum Test Parameters 11 parameters
Excess Urine Management Automatic absorption

Data Management and Connectivity

The analyzer combines onboard result storage, printing and serial communication functions to support routine laboratory record management.

Result Storage Up to 1,000 test results
Built-In Printer Thermal printer
External Printer External printer interface available
Communication Interface RS232
Baud Rate 9600 bps
PC Connectivity Supported through RS232 communication
LIS Integration Subject to communication protocol and laboratory system confirmation

Automatic Excess Urine Absorption

After the urine test strip is placed into the analyzer, the integrated excess-liquid management mechanism helps remove unnecessary urine remaining on the strip.

This function supports more consistent strip handling and helps reduce residual liquid and sample-to-sample carryover during routine laboratory workflows.

8, 10 and 11-Parameter Strip Options

The analyzer supports different urine reagent strip configurations according to laboratory screening requirements.

  • 8-parameter urine test strips.
  • 10-parameter urine test strips.
  • 11-parameter urine test strips.
  • Final strip brand and model compatibility should be confirmed before ordering.
  • The required parameter combination should be confirmed according to the laboratory testing protocol.

Operating Interface and Printing

The compact benchtop design integrates the operating display, keypad, urine strip testing position and thermal printer into a single laboratory instrument.

English and Chinese operating interfaces are available according to the supplied configuration. Test results can be stored internally and printed directly using the built-in thermal printer.

Before Ordering

Please provide the following information so the urine analyzer, reagent strip configuration and laboratory requirements can be confirmed before quotation.

  • Required quantity.
  • Destination country.
  • Required 8-, 10- or 11-parameter configuration.
  • Required urine test parameters.
  • Expected daily testing volume.
  • Required urine reagent strip supply.
  • Required operating language.
  • Whether PC or laboratory-system connectivity is required.
  • Required printer configuration.
  • Any tender, registration or documentation requirements.

Frequently Asked Questions

What type of urine analyzer is this?

It is a semi-automatic urine analyzer designed for urine reagent strip testing in clinical and diagnostic laboratories.

How many urine parameters can be tested?

The analyzer supports 8-, 10- and 11-parameter strip configurations. The 11-parameter configuration includes VC, LEU, NIT, URO, PRO, pH, BLD, SG, KET, BIL and GLU.

What is the testing speed?

The specified maximum testing speed is up to 120 tests per hour in continuous test mode.

How does the analyzer handle excess urine on the strip?

An automatic excess urine absorption mechanism helps remove residual liquid from the strip and reduce carryover during routine testing.

How many results can be stored?

The analyzer can store up to 1,000 test results.

Does the analyzer have a printer?

Yes. A built-in thermal printer is provided for routine test-result printing.

Can the analyzer connect to a computer or LIS?

RS232 communication is available for PC connection. Any LIS integration should be confirmed according to the required communication protocol and laboratory information system before ordering.

Reviews

There are no reviews yet.

Be the first to review “Semi-Automated Urine Analyzer | 120 Tests/Hour Clinical Chemistry Equipment – UMY Medical”

Your email address will not be published. Required fields are marked *

Scroll to Top