+86 19925884840 [email protected] +86 19925884840
,

Autoclavable Adjustable Volume Pipette for Laboratory Liquid Handling

The UMY Autoclavable Adjustable Volume Pipette is designed for precise liquid handling in laboratory environments. Available in multiple volume ranges from 0.1–1 μL to 1000–10000 μL, it supports a variety of liquid transfer tasks across laboratory workflows.

The pipette features an autoclavable design that allows the designated sterilizable parts to be treated using high-pressure steam sterilization at 121°C for 15 minutes, following the specified preparation and handling procedures. Before sterilization, contaminants should be removed from the interior and exterior surfaces. After sterilization, the pipette should be cooled to room temperature and dried before reassembly.

For safe and effective sterilization, the temperature must not exceed 121°C. Additional disinfectants, cleaning agents, or sodium hypochlorite should not be used during high-temperature, high-pressure, or ultraviolet sterilization.

Categories: ,

Autoclavable Adjustable Volume Pipette for Laboratory Liquid Handling

The UMY Autoclavable Adjustable Volume Pipette is designed for laboratory liquid handling across a range of volume requirements. With multiple available volume ranges, it supports different liquid transfer applications in laboratory workflows.

The designated sterilizable parts can be sterilized at 121°C for 15 minutes according to the specified procedure. Proper cleaning, packaging, cooling, and drying are important steps in the sterilization process.

Key Features

Multiple Volume Ranges

Available in a selection of volume ranges from 0.1–1 μL to 1000–10000 μL to accommodate different laboratory liquid handling requirements.

Autoclavable Design

The designated sterilizable parts can undergo high-pressure steam sterilization at 121°C for 15 minutes, following the specified instructions.

Pre-Sterilization Cleaning

Contaminants should be removed from the interior and exterior of the pipette before the sterilization procedure begins.

Protective Packaging for Sterilization

Sterilizable parts should be packaged using suitable materials such as sterilization bags, aluminum foil, or kraft paper before sterilization.

Post-Sterilization Handling

After sterilization, allow the pipette to cool to room temperature, dry it, and reinstall the components as required.

Controlled Sterilization Conditions

The sterilization temperature must not exceed 121°C. Additional disinfectants, cleaning agents, and sodium hypochlorite should not be used during high-temperature, high-pressure, or ultraviolet sterilization.

Technical Specifications

Technical Parameter Specification Details
Product Type Autoclavable adjustable volume pipette
Available Volume Ranges 0.1–1 μL; 0.5–10 μL; 2–20 μL; 5–50 μL; 10–100 μL; 20–200 μL; 100–1000 μL; 500–5000 μL; 1000–10000 μL
Sterilization Method High-temperature, high-pressure steam sterilization for designated sterilizable parts
Sterilization Temperature 121°C maximum
Sterilization Duration 15 minutes
Pressure 1 bar, as stated in the supplied instructions; confirm the pressure reference and autoclave operating requirements before use
Packaging Materials Sterilization bags, aluminum foil, or kraft paper
Post-Sterilization Procedure Cool to room temperature, dry, and reinstall as required
Additional Chemical Agents Do not use additional disinfectants, cleaning agents, or sodium hypochlorite during high-temperature, high-pressure, or ultraviolet sterilization
  • Specifications and sterilization instructions are based on the supplied product information.
  • Only the designated sterilizable parts should be subjected to the specified sterilization procedure.
  • The supplied information does not specify accuracy, precision, material, product dimensions, or individual model numbers.

Applications

Routine Laboratory Liquid Handling

The range of available volumes supports liquid transfer tasks requiring different sample volumes.

Laboratory Sample Preparation

Multiple volume options can accommodate different liquid measurement and sample preparation workflows.

Laboratory Sterilization Procedures

The designated sterilizable parts can be processed according to the specified steam sterilization instructions when appropriate for the intended laboratory workflow.

System Configuration

The supplied product information identifies an autoclavable pipette available in multiple volume ranges. The exact model, included accessories, and components suitable for sterilization should be confirmed before ordering.

Please confirm the required volume range and the manufacturer’s sterilization instructions for the selected configuration before use.

Before Ordering

  • Required volume range and order quantity.
  • Intended laboratory application and liquid handling requirements.
  • Confirmation of the sterilizable components and applicable sterilization procedure.
  • Destination country and any applicable procurement requirements.

Request an Autoclavable Pipette Quote

Contact UMY Medical to discuss available volume ranges, product configurations, pricing, and export delivery requirements.

Frequently Asked Questions

What volume ranges are available?

The supplied information lists nine volume ranges: 0.1–1 μL, 0.5–10 μL, 2–20 μL, 5–50 μL, 10–100 μL, 20–200 μL, 100–1000 μL, 500–5000 μL, and 1000–10000 μL.

How should the designated parts be sterilized?

Remove contaminants from the interior and exterior, package the designated sterilizable parts using suitable sterilization packaging, and follow the specified 121°C, 15-minute procedure. Confirm the correct pressure setting and operating instructions before use.

What should be done after sterilization?

Allow the pipette to cool to room temperature, let it dry, and reinstall the components as required by the manufacturer’s instructions.

Can additional disinfectants or cleaning agents be used during sterilization?

The supplied instructions state not to use additional disinfectants, cleaning agents, or sodium hypochlorite during high-temperature, high-pressure, or ultraviolet sterilization.

Can the entire pipette be autoclaved?

The supplied information refers to the designated sterilizable parts. Confirm which components can be autoclaved using the manufacturer’s instructions before processing the pipette.

Reviews

There are no reviews yet.

Be the first to review “Autoclavable Adjustable Volume Pipette for Laboratory Liquid Handling”

Your email address will not be published. Required fields are marked *

Scroll to Top