+86 19925884840 [email protected] +86 19925884840
,

UMY-RP-LS01 X-Ray Lead Sheet for Radiation Shielding, 0.6–2.0 mm

UMY-RP-LS01 X-ray lead sheet is available in 0.6, 1.0, 1.5 and 2.0 mm thicknesses for radiation shielding in X-ray rooms and medical imaging facilities. Standard sheet size is 1000 × 2000 mm, with a minimum order quantity of 30 sheets per thickness.

SKU: UMY-RP-LS01 Categories: ,

UMY-RP-LS01 X-Ray Lead Sheet

The UMY-RP-LS01 X-ray lead sheet is designed for structural radiation shielding in medical imaging facilities, including X-ray rooms, radiology departments, control areas, protective partitions and shielded construction projects.

Available nominal lead thicknesses include 0.6 mm, 1.0 mm, 1.5 mm and 2.0 mm. The standard sheet format is 1000 × 2000 mm, allowing the material to be incorporated into walls, doors, barriers and other shielding structures according to the approved radiation-protection design.

The required shielding thickness should be determined according to the imaging equipment, room layout, workload, barrier location, surrounding occupancy and applicable local radiation-protection requirements.

Key Features

0.6–2.0 mm Thickness Options

Available nominal lead thicknesses include 0.6 mm, 1.0 mm, 1.5 mm and 2.0 mm for different structural radiation-shielding requirements.

1000 × 2000 mm Sheet Format

The standard sheet size is suitable for integration into wall systems, lead-lined doors, protective partitions and other structural shielding assemblies.

For Medical X-Ray Shielding

Designed for use in medical imaging environments requiring structural attenuation of ionizing radiation as part of the facility shielding design.

Multiple Project Applications

The lead sheet can be used in shielding projects for diagnostic radiography, CT, fluoroscopy, dental imaging and other X-ray environments when specified by the project design.

Project Quantity Supply

Lead sheets can be supplied according to the selected thickness, project quantity, construction schedule and destination requirements.

Wooden Crate Packing Available

Wooden crate packing can be arranged separately for transportation and export shipment according to the final order quantity and destination.

Applications

X-ray lead sheet is primarily used as a structural radiation-shielding material in hospitals, imaging centers and other facilities where diagnostic or interventional X-ray equipment is installed.

  • Diagnostic X-ray rooms.
  • Digital radiography rooms.
  • CT imaging rooms.
  • Fluoroscopy rooms.
  • C-arm procedure rooms.
  • Dental X-ray rooms.
  • Radiology control areas.
  • Lead-lined doors.
  • Shielded walls and partitions.
  • Medical imaging facility construction and renovation projects.

The application itself does not determine the required lead thickness. Final shielding specifications should be confirmed according to the individual project.

Available Lead Thicknesses

Nominal Thickness Standard Sheet Size Minimum Order Quantity
0.6 mm 1000 × 2000 mm 30 sheets
1.0 mm 1000 × 2000 mm 30 sheets
1.5 mm 1000 × 2000 mm 30 sheets
2.0 mm 1000 × 2000 mm 30 sheets

The minimum order quantity applies separately to each selected thickness. For example, an order containing both 1.0 mm and 1.5 mm sheets should meet the minimum quantity requirement for each thickness.

Technical Specifications

Model UMY-RP-LS01
Product Type X-Ray Radiation Shielding Lead Sheet
Material Lead (Pb)
Available Thicknesses 0.6 / 1.0 / 1.5 / 2.0 mm
Standard Sheet Size 1000 × 2000 mm
Supply Form Lead sheet / lead plate
Main Application Structural radiation shielding
MOQ 30 sheets per thickness
Packing Wooden crate available separately

Radiation Shielding Planning

Lead-sheet thickness should be selected as part of the complete radiation-shielding design of the imaging room rather than only according to the equipment category.

Important project factors can include:

  • X-ray generator and operating parameters.
  • Expected examination workload.
  • Primary and secondary barrier locations.
  • Distance between the radiation source and adjacent areas.
  • Occupancy of surrounding rooms and spaces.
  • Wall, ceiling, floor and door construction.
  • Equipment orientation and primary beam direction.
  • Local radiation-protection requirements.

The final shielding specification should be confirmed by the project shielding design, medical physicist, radiation-protection professional or other competent authority responsible for the facility.

Installation Considerations

The effectiveness of structural radiation shielding depends on both the selected lead thickness and the continuity of the completed barrier.

  • Install the lead sheet according to the approved shielding design.
  • Maintain continuous shielding coverage across joints and seams.
  • Doors, frames, electrical boxes and service penetrations require appropriate shielding treatment.
  • Avoid unnecessary openings through the shielding layer.
  • Lead sheet is normally incorporated behind wall panels, doors or other protective finishing materials.
  • Completed shielding may require inspection or radiation survey before clinical operation according to local requirements.

Packing and Project Supply

Lead sheet is a high-density shielding material, so packing and transportation should be planned according to the selected thickness, number of sheets and shipping destination.

  • Minimum order quantity: 30 sheets per thickness.
  • Different thicknesses are subject to their own minimum quantities.
  • Wooden crate packing is available separately.
  • Final sheets per crate should be confirmed according to order configuration.
  • International freight should be calculated according to final gross weight, packing method and destination.

Before Ordering

Please provide the following information so the lead-sheet specification, quantity, packing and shipping requirements can be confirmed before quotation.

  • Required lead thickness: 0.6, 1.0, 1.5 or 2.0 mm.
  • Required quantity for each thickness.
  • Destination country and delivery location.
  • Type of X-ray room or radiation-shielding project.
  • Whether a shielding calculation or project specification is available.
  • Required wall, door or partition application.
  • Required packing method.
  • Required material or tender documentation.
  • Expected delivery schedule.

To learn more about X-ray products, click “X-Ray Machine” to view details.

Frequently Asked Questions

What lead-sheet thicknesses are available?

The UMY-RP-LS01 is available in nominal thicknesses of 0.6 mm, 1.0 mm, 1.5 mm and 2.0 mm.

What is the standard sheet size?

The current standard sheet format is 1000 × 2000 mm.

What is the minimum order quantity?

The minimum order quantity is 30 sheets for each selected thickness.

Which lead thickness should be used for an X-ray room?

The required thickness cannot be selected only according to the room name or imaging modality. It should be determined from the shielding calculation, equipment parameters, workload, room layout, surrounding occupancy and applicable local requirements.

Can this lead sheet be used for CT room shielding?

Yes, lead sheet can be incorporated into CT-room shielding structures when specified by the approved shielding design. The required thickness should be confirmed for the individual project.

Is wooden crate packing available?

Yes. Wooden crate packing can be arranged separately according to the order quantity and transportation requirements.

What information is needed for quotation?

Please provide the required thickness, quantity for each thickness, destination country, project application, packing requirements and any available shielding or tender specifications.

UME Contact Form#1

Reviews

There are no reviews yet.

Be the first to review “UMY-RP-LS01 X-Ray Lead Sheet for Radiation Shielding, 0.6–2.0 mm”

Your email address will not be published. Required fields are marked *

Scroll to Top