UMIRW003 Infant Radiant Warmer
The UMIRW003 infant radiant warmer is designed for newborn thermal care in delivery rooms, neonatal units and other clinical environments requiring open access to the infant during warming, observation and treatment.
The system uses overhead radiant heating with servo temperature control and skin-temperature monitoring to support controlled newborn warming. The open-care design allows medical staff to access the infant without the enclosure used in an incubator.
Its adjustable bed, rotatable radiant head, examination light and integrated X-ray cassette tray support routine neonatal care, observation and bedside procedures.
Key Features
Servo Temperature Control
Servo-controlled heating adjusts radiant output according to skin-temperature feedback, supporting stable thermal care during newborn observation and treatment.
Skin Temperature Monitoring
The system displays skin temperature and selected temperature settings to support continuous thermal monitoring during neonatal care.
Adjustable Radiant Head
The radiant heating head can be rotated to improve access to the newborn during examination, nursing procedures and clinical treatment.
Tilting Infant Bed
The bed platform can be tilted to support positioning requirements during newborn care and clinical procedures.
Examination Light
An integrated examination light provides additional illumination for newborn observation and bedside procedures.
X-Ray Cassette Tray
An integrated X-ray cassette tray supports bedside radiographic procedures without unnecessary transfer of the infant.
Quartz Infrared Heating Source
The radiant warmer uses a quartz infrared heating element designed to provide overhead thermal support for newborn care.
Open-Access Neonatal Care
The open-bed configuration allows clinicians and nursing staff to maintain direct access to the infant during stabilization, observation and treatment.
Applications
The UMIRW003 is suitable for newborn thermal care and open-access clinical management in hospitals and maternity facilities.
- Delivery rooms.
- Neonatal intensive care units.
- Newborn observation areas.
- Maternity hospitals.
- Post-delivery thermal stabilization.
- Newborn examination and nursing procedures.
- Bedside neonatal treatment.
- Newborn radiographic procedures using the integrated cassette tray.
Temperature Control and Heating
The UMIRW003 combines radiant heating with servo temperature control to support newborn thermal management while maintaining open access to the patient.
- Servo temperature-control mode.
- Skin-temperature monitoring.
- Display of selected temperature and heating output.
- Overhead infrared radiant heating.
- Adjustable radiant head for clinical access.
The selected temperature settings and heating mode should be used according to the infant’s clinical condition and the facility’s neonatal-care protocol.
Technical Specifications
| Model | UMIRW003 |
|---|---|
| Product Type | Infant Radiant Warmer |
| Temperature Control | Servo temperature control |
| Temperature Monitoring | Skin-temperature monitoring |
| Sensor Accuracy | ≤0.3°C |
| Temperature Rise Time | ≤45 min |
| Mattress Temperature Uniformity | ≤2.0°C |
| Heating Output | 0–100% |
| Radiant Head Adjustment | 0–90° rotation |
| Bed Tilt | Approximately ±10° |
| Mattress Tray Size | Approx. 680 × 540 mm |
| Heating Source | Quartz infrared radiant heater |
| Examination Light | Integrated |
| X-Ray Cassette Tray | Integrated |
Newborn Care Workflow
The open-care design allows clinicians to perform warming, observation and routine procedures while maintaining direct access to the newborn.
The infant can remain on the warmer during temperature monitoring, examination and selected bedside procedures, reducing unnecessary movement during early neonatal care.
Bed and Clinical Access
The adjustable bed and movable radiant head are designed to improve access during newborn care.
- Tilting infant bed for positioning.
- Rotatable radiant head for procedural access.
- Integrated examination lighting.
- Open sides for nursing and clinical procedures.
- X-ray cassette tray for bedside imaging workflows.
Before Ordering
Please provide the following information so the required configuration and quotation can be confirmed.
- Intended department and clinical application.
- Required temperature-control mode.
- Required alarm and monitoring functions.
- Required bed and accessory configuration.
- Need for X-ray cassette tray.
- Required examination lighting.
- Required IV pole, shelves or accessory trays.
- Destination country.
- Local power supply requirements.
- Installation and operator-training requirements.
Frequently Asked Questions
What is the UMIRW003 infant radiant warmer used for?
The UMIRW003 is designed for newborn warming, thermal stabilization, observation and open-access neonatal procedures in delivery rooms and neonatal care areas.
Does the warmer support servo temperature control?
Yes. The system uses servo temperature control with skin-temperature feedback to adjust heating output during neonatal care.
Can the infant remain accessible during treatment?
Yes. Unlike an enclosed infant incubator, the radiant warmer uses an open-bed design that allows direct access to the newborn during examination, nursing and selected procedures.
Does the warmer include an X-ray cassette tray?
Yes. The UMIRW003 configuration includes an integrated X-ray cassette tray for bedside neonatal radiographic procedures.
Can the bed and radiant head be adjusted?
Yes. The infant bed can be tilted for positioning, and the radiant head can be rotated to improve clinical access.
What information should be provided before quotation?
Please provide the intended department, required temperature-control functions, accessories, destination country, power supply and any installation or training requirements.