Integrated Bubble CPAP for Neonatal and Pediatric Respiratory Support
The UMH-ADI Bubble CPAP System is a non-invasive respiratory support system designed for neonatal and pediatric care. It provides continuous positive airway pressure (CPAP) through a bubble generator, combined with adjustable air-oxygen mixing and humidified breathing gas delivery.
The system integrates an air-oxygen blender, humidifier, bubble CPAP generator, breathing circuit and patient interface. These components work together to provide a configurable CPAP setup for spontaneously breathing patients requiring positive airway pressure support.
The UMH-ADI is available with or without a medical air compressor. Different humidifiers, breathing circuits and nasal interfaces may be selected according to patient requirements, hospital infrastructure and the confirmed equipment configuration.
Key Features
Integrated Bubble CPAP Design
Combines air-oxygen blending, humidification, bubble CPAP generation, breathing circuit components and a patient interface in one configurable system.
Adjustable Oxygen Concentration
The air-oxygen blender provides a manufacturer-specified FiO₂ adjustment range of 21–100%, allowing oxygen concentration to be selected according to clinical requirements.
Adjustable CPAP Pressure
The bubble generator provides a CPAP pressure setting range of 3–10 cmH₂O using the water-column adjustment mechanism.
Gas Flow Control
The system supports an adjustable gas flow range of 2–18 L/min. Flow, oxygen concentration and pressure settings can be visually checked during operation.
Humidification Options
A standard humidification configuration is available, with alternative humidifiers and an optional heated-wire breathing circuit solution described in the product catalog.
Optional Medical Air Compressor
The UMH-4000 medical air compressor can be included in the selected configuration where a compatible medical air supply is required.
Bubble CPAP Respiratory Support and Operation
The UMH-ADI delivers a blended air-oxygen mixture through a humidification system and breathing circuit. A bubble generator creates continuous positive airway pressure through a submerged expiratory tube and water-column adjustment.
Air-Oxygen Blending
The blender allows selection of the supplied oxygen concentration. The system requires compatible medical gas connections and appropriate supply pressures.
Bubble Pressure Generation
CPAP pressure is adjusted through the bubble generator within the specified 3–10 cmH₂O range.
Gas Humidification
The humidifier and breathing circuit support delivery of conditioned breathing gas through the selected patient interface.
Patient Interface Selection
Different nasal prong and interface options are described in the supplier documentation. Appropriate sizes and configurations should be confirmed for the intended patient population.
Clinical use, pressure selection, oxygen settings and patient monitoring must follow the responsible clinician’s assessment and the applicable operating instructions.
Technical Specifications
The following specifications are based on the supplied UMH-ADI Bubble CPAP catalog. Final electrical, component and interface configurations should be verified before procurement.
| Specification | UMH-ADI |
|---|---|
| Product Type | Bubble Continuous Positive Airway Pressure System |
| Model | UMH-ADI |
| Respiratory Support Method | Non-invasive Bubble CPAP |
| Manufacturer-Listed Patient Population | Premature neonates and pediatric patients up to 14 years; suitability depends on patient and interface selection |
| FiO₂ Range | 21–100% |
| Gas Flow Rate | 2–18 L/min |
| CPAP Pressure | 3–10 cmH₂O |
| Noise Level | ≤55 dB(A), manufacturer-listed |
| Standard Power Supply | AC 220V, 50–60Hz |
| Optional Power Supply | AC 110V, 50–60Hz |
| Medical Gas Supply | Air / Oxygen at 0.3–0.4 MPa |
| Gas Supply Alarm Condition | Air-oxygen supply pressure difference greater than 0.1 MPa, as specified by the manufacturer |
| Operating Temperature | 5–40°C |
| Storage Temperature | -20 to 55°C |
| Medical Air Compressor | UMH-4000, optional |
| Humidification | Standard humidifier; alternative configurations available |
| Patient Connection | Nasal interface and breathing circuit configuration |
- The catalog lists an age range extending to 14 years. Clinical suitability must be evaluated with the selected patient interface and the complete operating instructions.
- The optional air compressor supplies medical air; a compatible oxygen source is still required for oxygen blending.
- Humidifier part numbers differ between sections of the supplied catalog. The exact current humidifier model should be confirmed before quotation.
- All specifications are subject to the confirmed configuration and current manufacturer documentation.
System Configuration Options
The UMH-ADI can be supplied in configurations with or without a medical air compressor. Selection depends on available hospital gas infrastructure and the required respiratory support equipment package.
| Configuration | Description |
|---|---|
| UMH-ADI with Medical Air Compressor | Bubble CPAP system configuration including a medical air compressor, air-oxygen blender, CPAP generator, humidification and breathing circuit components. |
| UMH-ADI without Medical Air Compressor | Bubble CPAP system configuration for facilities with an appropriate external medical air supply and oxygen source. |
| Optional Heated-Wire Configuration | Alternative humidification configuration with heated-wire breathing circuit, compatible humidifier and related accessories, subject to confirmation. |
The exact included items, connections and accessories should be identified in the quotation. The air compressor and heated-wire configuration should not be assumed to be included with every system.
System Components and Accessories
The supplier documentation identifies the following components for the UMH-ADI system. The final scope of supply depends on the selected configuration.
| Component | Function / Configuration |
|---|---|
| Air-Oxygen Blender | Adjusts oxygen concentration and blended gas flow. |
| Bubble CPAP Generator | Provides water-column-based pressure adjustment within the specified CPAP range. |
| Humidifier | Supports humidification of breathing gas delivered through the circuit. |
| Reusable Humidification Chamber | Chamber supplied with the applicable standard humidification configuration. |
| Reusable Breathing Circuit | Breathing circuit kit with water trap, subject to confirmed supply list. |
| Circuit Support Arm | Supports the breathing circuit during equipment setup. |
| Mobile Trolley | Provides a mobile support structure for the CPAP system. |
| Horizontal Nasal Prong Kit | Patient interface components; sizes and quantities must be confirmed. |
| Medical Air Compressor | Optional UMH-4000 compressor, included only in the corresponding configuration. |
The catalog also describes alternative nasal interface kits. Hospitals should confirm patient interface types, compatible sizes, reusable or disposable components, and replacement consumables before purchasing.
Humidification and Heated-Wire Breathing Circuit Options
Different humidification configurations are available for the UMH-ADI. The standard system uses a humidifier and reusable breathing circuit, while the supplier also describes an optional heated-wire breathing circuit arrangement.
Standard Humidification
Uses the compatible humidifier, reusable chamber and breathing circuit included in the selected standard configuration.
Heated-Wire Circuit Option
The catalog describes an optional single-use heated-wire breathing circuit with a compatible servo-controlled respiratory humidifier.
Auto-Fill Chamber Option
An auto-fill humidification chamber is shown as part of the optional heated-wire configuration. Its inclusion should be confirmed separately.
Interface and Circuit Compatibility
Patient interfaces, circuit connections and humidifier compatibility should be reviewed together to establish the correct system configuration.
Clinical Applications
The UMH-ADI Bubble CPAP System is designed for non-invasive respiratory support in neonatal and pediatric care environments under qualified clinical supervision.
Neonatal Care Units
Provides a configurable bubble CPAP system for neonatal respiratory support where continuous positive airway pressure is clinically indicated.
Neonatal Intensive Care Units
Supports respiratory care workflows requiring air-oxygen blending, humidification and bubble CPAP pressure generation.
Pediatric Respiratory Care
The manufacturer lists pediatric use within a defined age range. Actual suitability requires assessment of the patient, interface and respiratory support requirements.
Hospital Respiratory Equipment Procurement
Available configurations support procurement planning for facilities with different medical air supply arrangements.
The system is intended for spontaneously breathing patients. It is not a replacement for an invasive mechanical ventilator, and its use must follow the manufacturer instructions and clinical requirements.
Before Ordering
To confirm the appropriate UMH-ADI Bubble CPAP configuration and prepare an accurate quotation, please provide:
- Required quantity and destination country.
- Intended clinical department: neonatal care, NICU or pediatric respiratory care.
- Whether a medical air compressor is required.
- Available medical air and oxygen supply connections and pressures.
- Required FiO₂, flow and CPAP pressure operating ranges.
- Standard or heated-wire humidification requirements.
- Required breathing circuit type and patient interface sizes.
- Local electrical supply: 220V or optional 110V.
- Required reusable components, disposable accessories and spare parts.
- Installation, user training and after-sales requirements.
- Required technical, regulatory or tender documentation.
UMY Medical can review the specified equipment package and provide a quotation based on the confirmed configuration. Final accessories, delivery arrangements and commercial terms should be agreed before ordering.
Before Ordering
- Required order quantity and destination country.
- Transducer probe model selections and specialized application software packages.
- Electrical power supply standards and accessory requirements.
Request a UMH-ADI Bubble CPAP System Quote
Contact UMY Medical to discuss the UMH-ADI Bubble CPAP System for neonatal and pediatric respiratory support, including humidifier selection, medical air compressor options, breathing circuits and patient interfaces.
Please include your destination country, required quantity and preferred configuration so our team can review your requirements before preparing a quotation.
Frequently Asked Questions
What is the CPAP pressure range of the UMH-ADI?
The UMH-ADI provides a manufacturer-specified CPAP pressure adjustment range of 3–10 cmH₂O, using a bubble generator with a water-column pressure adjustment mechanism.
Can the UMH-ADI adjust oxygen concentration?
Yes. The system includes an air-oxygen blender with a specified FiO₂ range of 21–100%. Compatible medical gas supplies and appropriate clinical monitoring are required.
Is the medical air compressor included?
The UMH-ADI is available with or without a medical air compressor. The UMH-4000 compressor is included only when the corresponding configuration is ordered. The standard supply list should be confirmed before purchasing.
Is a heated-wire breathing circuit available?
The supplier catalog describes an optional heated-wire breathing circuit configuration with compatible humidification components. Availability and the exact included accessories must be confirmed in the quotation.








Reviews