Portable Transcutaneous Bilirubin Meter for Newborn Jaundice Screening
This transcutaneous bilirubin meter is designed for rapid, non-invasive bilirubin screening in newborns. By taking measurements through the skin, it can support neonatal jaundice screening workflows without requiring a blood sample for each routine check.
The handheld device combines a 1.3-inch TFT color display, rapid one-second measurement, Bluetooth connectivity, dual-unit display in mg/dL and μmol/L, and storage for recent measurement records. Its compact design makes it suitable for neonatal departments, maternity wards, maternal and child health facilities and other newborn care environments.
Key Features
Non-Invasive Bilirubin Screening
The device performs transcutaneous bilirubin measurement through the skin, supporting routine newborn jaundice screening without blood collection for every measurement.
Rapid One-Second Measurement
A measurement can be completed in approximately one second, helping clinical staff perform repeated bilirubin screening efficiently.
1.3-Inch TFT Color Display
The 240 × 240 color screen displays measurement results, average values, battery status and measurement units in a compact handheld interface.
Bluetooth Data Transmission
Bluetooth connectivity supports transfer of measurement records to a compatible smartphone application for data review and management.
mg/dL and μmol/L Units
Measurement units can be switched between mg/dL and μmol/L to suit different clinical and regional reporting practices.
20-Record Data Storage
The device can store the latest 20 measurements for cyclic viewing and short-term record review.
Rechargeable Battery
A built-in 3.7V 800mAh rechargeable lithium-ion battery supports portable operation and Type-C charging.
Portable Handheld Design
The compact form factor is convenient for neonatal wards, maternity departments and other clinical environments where repeated bedside screening may be required.
Typical Clinical Applications
- Neonatal jaundice screening.
- Routine transcutaneous bilirubin checks in newborns.
- Neonatology departments.
- Maternity and postnatal wards.
- Maternal and child health hospitals.
- Pediatric and newborn care facilities.
- Follow-up assessment where transcutaneous bilirubin screening is appropriate.
Transcutaneous bilirubin measurement is a screening and monitoring tool. Clinical interpretation and the need for confirmatory laboratory testing should be determined according to the healthcare provider’s clinical protocol.
Measurement Performance
| Measurement Method | Transcutaneous, Non-Invasive |
|---|---|
| Measurement Range | 0.0–25.0 mg/dL / 0–425 μmol/L |
| Accuracy, 0–15.9 mg/dL | ±1 mg/dL / ±17 μmol/L |
| Accuracy, 16–25 mg/dL | ±1.5 mg/dL / ±25.5 μmol/L |
| Display Resolution | 0.1 mg/dL or 1 μmol/L |
| Repeatability | <10% |
| Measurement Time | Approximately 1 Second |
| Measurement Units | mg/dL / μmol/L |
Technical Specifications
| Product Type | Transcutaneous Bilirubin Meter |
|---|---|
| Application | Neonatal Jaundice Screening |
| Display | 1.3-Inch TFT Color Display |
| Display Resolution | 240 × 240 |
| Data Storage | 20 Recent Measurements |
| Wireless Connection | Bluetooth |
| Battery | 3.7V 800mAh Rechargeable Li-Ion Battery |
| Charging Interface | Type-C |
| Measurement Range | 0.0–25.0 mg/dL / 0–425 μmol/L |
| Measurement Units | mg/dL / μmol/L |
| Measurement Time | Approximately 1 Second |
Display and Data Management
Multi-Position Measurement Display
The color display can present individual measurement results and an average value to support repeated measurement workflows.
Recent Measurement Review
Up to 20 recent measurement records can be stored and reviewed directly from the device.
Smartphone Connectivity
Bluetooth communication allows compatible mobile devices to receive measurement data for further record management and review.
Before Ordering
Please provide the following information when requesting a quotation for this transcutaneous bilirubin meter:
- Required quantity.
- Destination country.
- Hospital, distributor or project application.
- Required language or user-interface requirements.
- Required accessories and packaging.
- Any tender specifications or technical documentation requirements.
Request a Transcutaneous Bilirubin Meter Quote
Contact UMY Medical for product configuration, quantity pricing, export quotation and distributor inquiries for transcutaneous bilirubin meters.
Send Your Requirements
Please provide your required quantity, destination country and intended clinical or distribution application.
Frequently Asked Questions
Does this bilirubin meter require a blood sample?
No. It is designed for transcutaneous bilirubin measurement through the skin and does not require blood collection for each routine screening measurement.
What is the measurement range?
The listed measurement range is 0.0–25.0 mg/dL, corresponding to 0–425 μmol/L.
How quickly can a measurement be completed?
A transcutaneous measurement can be completed in approximately one second.
Can the device store previous measurements?
Yes. The device stores up to 20 recent measurement records for review.








Reviews