Digital Radiography and Fluoroscopy (DRF) System for Advanced High-Precision Imaging
Quick Info.
- SKU NO.: UMY-XM-045
- Device Classification: Class Ⅱ
- Warranty: 1 Year
- Power Source: Electric
- Transport Package: Carton or Wooden Cases
- Origin: China
- Material: Aluminum and magnesium alloys
- After-Sale Service: Online Technical Support
- Production Capacity: 500 Sets/Year
The Digital Radiography and Fluoroscopy (DRF) System offers advanced imaging technology for high-precision diagnostics. Combining the benefits of digital radiography with real-time fluoroscopy, this system ensures clear, detailed images for a wide range of applications, including orthopedics, cardiology, and gastrointestinal procedures. It provides accurate, high-resolution images with minimal radiation exposure, enhancing both patient safety and diagnostic efficiency. Ideal for hospitals and specialized imaging centers, this DRF system supports rapid decision-making and precise treatment planning. Its advanced features make it an indispensable tool for healthcare professionals seeking superior imaging capabilities in complex diagnostic procedures.
The Specific Parameters
| ITEMS | PARAMETERS |
|---|---|
| Power Supply | |
| Voltage | 380V ± 38V |
| Frequency | 50Hz ± 1Hz |
| Capacity | ≥65kVA |
| Internal Resistance | ≤0.17Ω |
| Generator | |
| Power | 80kW |
| Inverter Frequency | 440kHz |
| Radiography Tube Voltage | 40kV ~ 150kV step adjustment |
| Radiography Tube Current | 10mA ~ 1000mA step adjustment |
| Radiography Time | 1.0ms ~ 10,000ms step adjustment |
| Radiography mAs | 0.1mAs ~ 1000mAs |
| Fluoroscopy Tube Voltage | 40kV ~ 125kV step adjustment |
| Fluoroscopy Tube Current | 0.5mA ~ 10mA (continuous fluoroscopy), 5mA ~ 20mA (pulse fluoroscopy) |
| X-Ray Tube Assembly | |
| Target | Molybdenum-based lanthanum-tungsten composite |
| Target Angle | 12° |
| Nominal Tube Voltage | 150kV |
| Tube Focus (Big/Small) | 1.2mm / 0.6mm |
| Input Power | Big Focus: 100kW, Small Focus: 40kW |
| Anode Thermal Capacity | 420kJ (600kHU) |
| Anode Maximum Heat Dissipation | 1750W (2465kHU/min) |
| Component Heat Capacity | 1420kJ (2000kHU) |
| Anode Rotation Speed | 9700rpm |
| Collimator | |
| Field of View Light | Halogen lamp, AC24V/100W |
| Visible Light Illumination | Average illumination brightness > 100LUX |
| Light Field Exposure Time | 5 ~ 45s, 5s per step |
| Diagnostic Table | |
| Table Transverse Movement Distance | 300mm |
| SID | 1100mm ~ 1800mm |
| Table Panel Equivalent Filtration | ≤1.2mmAl |
| Point Device Movement Range | 1250mm |
| Table Height from Ground | 905mm |
| Table Size | 2100mm × 730mm |
| Table Rotation | +90° ~ -25° |
| X-Ray Tube Column Swing | +40° ~ 0° ~ -40° |
| Minimum Distance of Compressor from Table Surface | ≤150mm |
| Compressor Pressure | 80N ~ 130N |
| Table Bearing | 135kg |
| Fragmentation | Whole film, two-piece, four-slice |
| Fixed Grid | |
| Grid Density | 103L/INCH |
| Ratio | 0.41736111111111 |
| Convergence Distance | 130cm |
| Stationary Type | 15″ × 18″ |
| Intensifier | |
| Field of View Size | 230mm |
| Resolution | 52 Lp/cm |
| Conversion Factor | 26 |
| Signal-to-Noise Ratio | 45 dB |
| X-Ray Camera | |
| Cell Size | 5.86 × 5.86µm |
| Number of Valid Pixels | 1920 × 1200 |
| Flat Panel Detector | |
| Image Sensor | Amorphous silicon thin-film transistor |
| Pixel Size | 143µm |
| Effective Pixel Size | 3008(H) × 3072(V) |
| Effective Area (H × V) | 430(H) × 439(V) |
| Gray Scale | 14-bit |
| Spatial Resolution | 3.7 Lp/mm (CsI) |
| Energy Range | 40kV ~ 150kVP |
| Power Input | DC24V |