Contrast Media Injector CSP with Bluetooth and Waterproof Design for CT Imaging
SKU: UMY-XM-059
Brand: Umy
MOQ: 1
Origin: China
Quick Info.
- SKU NO.: UMY-XM-059
- Device Classification: Class Ⅱ
- Warranty: 1 Year
- Power Source: Electric
- Transport Package: Carton or Wooden Cases
- Origin: China
- Material: Aluminum and magnesium alloys
- After-Sale Service: Online Technical Support
- Production Capacity: 500 Sets/Year
The CSP Contrast Media Injector is a cutting-edge device designed for CT imaging, featuring Bluetooth connectivity and a waterproof design for enhanced durability. It enables precise contrast agent delivery, improving the quality of CT scans and ensuring accurate diagnosis. The Bluetooth capability allows for seamless integration with imaging systems, streamlining workflow and enhancing efficiency. Its waterproof design ensures reliability in various clinical environments, providing peace of mind during critical imaging procedures. This injector is essential for healthcare professionals seeking a versatile, high-performance solution for contrast media administration in CT imaging.
The Specific Parameters
ITEMS | PARAMETERS |
---|---|
Weight | |
Scan Room Unit Weight | 23.7 kg |
Control Room Unit Weight | 5 kg |
Power | |
Power Box AC Cable Length | 1.8 meters |
Injector Power Cable Length | 10 meters |
Power Box | 24V, 6.5A Switching Power Supply |
Syringe Specifications | 200 mL |
Injection Specifications | |
Volume (Syringe A) | 1 mL – 200 mL |
Flow Rate (Configurable) | 0.1 – 10 mL/s (increments of 0.1 mL/s) |
Pressure Limit | 325 PSI |
Delay Time | 1 – 300 s (increments of 1 s) |
Pause Phase | 1 – 900 s (increments of 1 s) |
Injection Phases | 6 injection phases |
Storage Capacity | Up to 100 injection records (each record can contain 6 injection phases, records retained after power-off) |
Piston Rod Control | |
Forward/Retract Motion | Controlled |
Lowest Speed | 1 mL/s |
Highest Speed | 9.9 mL/s |
Retract Speed | 8 mL/s |
EMI/RFI | |
Standards Compliance | IEC 60601-1 and IEC 60601-1-2 |
Power Supply Requirements | |
Voltage | 100-240 VAC |
Frequency | 50/60 Hz |
Power | 200 VA |
Leakage Current | |
Injector Leakage Current | <100 μA |
Patient Leakage Current | <10 μA |
Ground Connection | |
Resistance (Earth Pin to Exposed Metal) | <0.1 ohms |
Environmental Requirements | |
Temperature | -13°C to 70°C (-40°F to +158°F) |
Humidity | 5% to 100% R.H., non-condensing |
Air Pressure | 48 kPa to 110 kPa |
Performance Considerations | |
Operating Temperature | +10°C to +40°C (+50°F to +104°F) |
Operating Humidity | 20% to 90% R.H. |
Operating Air Pressure | 69 kPa to 110 kPa |